Our company specialized in Cable/Electrical Wire/ Conductor product
0.6-1KV PVC INSULATION ARMORED POWER CABLE
type:0.6/1kV CU or AL /PVC/PVC/SWA/PVC
standard:IEC 60502-1
construction:CU or AL /PVC/PVC/SWA/PVC or CU or AL /PVC/PVC/AWA/PVC
rating voltage:0.6/1kV
conductor material:CU or AL,
insulation material:PVC
armor construction:Steel wire armoured(SWA)
sheath material:PVC
specification or package can be produced as your request.
INQUIRYApplication
Power cable suitable for construction of underground supply and distribution
grids and installations of industrial and public projects, for street
lighting, for transmission and distribution of electric power at nominal
voltage U0/U 0,6/1 kV.
The concentric conductor is used as a screen and could be used as
neutral (N), earthing (PE), and both as neutral and earthing (PEN) conductor,
but not as an external conductor.
Construction
• Solid or stranded Cu or AL wires cl. 1 or cl. 2
• Description of the wire’s shape
re - round solid
rm - round multi-core
sm - sector multi-core
• Insulation: PVC compound
• Inner sheath: filling compound
• Armoring: Steel wire armoured
• Wrapping: polymer tape
• Outer sheath: PVC compound
• Outer sheath colour: black
600 / 1000 V – THREE CORE COPPER CONDUCTOR PVC INSULATED STEEL WIRE ARMOURED PVC SHEATHED CABLES
(CU/PVC/PVC/SWA/PVC and CU/PVC/SWA/PVC)
Nominal Area of Conductor | Maximum Conductor Resistance at 20°C | Thickness of Insulation | Thickness of Extruded Bedding | Armour Wire Diameter | Thickness of Outer Sheath | Approx.Overall Diameter | Approx.Cable Weight | Standard Packing Length | Drum Size | Approx.Gross Weight |
Sqmm | Ohm/Km | mm | mm | mm | mm | mm | Kg/Km | Yard/ Metre±10% | KG | |
50 | 0.387 | 1.4 | 1 | 1.25 | 1.8 | 19.9 | 820 | 500 | D-10 | 470 |
70 | 0.268 | 1.4 | 1 | 1.25 | 1.8 | 21.5 | 1060 | 500 | D-10 | 590 |
95 | 0.193 | 1.6 | 1 | 1.25 | 1.8 | 23.8 | 1380 | 500 | D-11 | 790 |
120 | 0.153 | 1.6 | 1 | 1.6 | 1.8 | 26 | 1680 | 500 | D-12 | 955 |
150 | 0.124 | 1.8 | 1 | 1.6 | 1.8 | 27.8 | 2030 | 500 | D-12 | 1125 |
185 | 0.0991 | 2 | 1 | 1.6 | 1.8 | 29.8 | 2420 | 500 | D-12 | 1320 |
240 | 0.0754 | 2.2 | 1 | 1.6 | 1.9 | 32.9 | 3050 | 500 | D-16 | 1740 |
300 | 0.0601 | 2.4 | 1 | 2 | 2 | 36.3 | 3800 | 500 | D-16 | 2110 |
400 | 0.047 | 2.6 | 1.2 | 2 | 2.1 | 40.2 | 4810 | 500 | D-18 | 2650 |
500 | 0.0366 | 2.8 | 1.2 | 2 | 2.2 | 43.8 | 5920 | 500 | D-18 | 3200 |
630 | 0.0283 | 2.8 | 1.2 | 2 | 2.4 | 49.8 | 7420 | 250 | D-16 | 2065 |
800 | 0.0221 | 2.8 | 1.4 | 2.5 | 2.5 | 55.4 | 9500 | 250 | D-18 | 2610 |
1000 | 0.0176 | 3 | 1.4 | 2.5 | 2.6 | 61.6 | 11880 | 250 | D-18 | 3215 |
All the cables are insulated with either PVC Type 5 Heat Resisting 85°C compound and sheathed with PVC
Type 9/ ST2 compound OR PVC Type A/Til compound and sheathed with PVC Type ST1/TM1 compound.
Colour of insulation and sheath black.
All Cables conform to IEC 60502- 1.
600 /1000 V – TWO CORE COPPER CONDUCTOR PVC INSULATED STEEL WIRE ARMOURED PVC SHEATHED CABLES
(CU / PVC / PVC / SWA / PVC)
Nominal Area of Conductor | Maximum Conductor Resistance at 20°C | Thickness of Insulation | Thickness of Extruded Bedding | Armour Wire Diameter | Thickness of Outer Sheath | Approx.Overall Diameter | Approx.Cable Weight | Standard Packing Length | Drum Size | Approx.Gross Weight |
Sqmm | Ohm/Km | mm | mm | mm | mm | mm | Kg/Km | Metre±10% | KG | |
1.5* | 12.1 | 0.7 | 0.8 | 0.9 | 1.3 | 12.6 | 305 | 1000 | D-9 | 365 |
1.5 | 12.1 | 0.7 | 0.8 | 0.9 | 1.4 | 13.2 | 310 | 1000 | D-9 | 370 |
2.5* | 7.41 | 0.8 | 0.8 | 0.9 | 1.4 | 14 | 370 | 1000 | D-10 | 430 |
2.5 | 7.41 | 0.8 | 0.8 | 0.9 | 1.4 | 14.4 | 390 | 1000 | D-10 | 450 |
4 | 4.61 | 0.8 | 0.8 | 0.9 | 1.4 | 15.4 | 460 | 1000 | D-11 | 560 |
6 | 3.08 | 0.8 | 0.8 | 0.9 | 1.5 | 16.8 | 550 | 1000 | D-11 | 650 |
10 | 1.83 | 1 | 0.8 | 1.25 | 1.6 | 19.9 | 835 | 1000 | D-12 | 945 |
16 | 1.15 | 1 | 0.8 | 1.25 | 1.6 | 22.1 | 1050 | 1000 | D-14 | 1200 |
25** | 0.727 | 1.2 | 1 | 1.6 | 1.7 | 26.8 | 1610 | 500 | D-12 | 915 |
35** | 0.524 | 1.2 | 1 | 1.6 | 1.8 | 29.2 | 1950 | 500 | D-12 | 1090 |
50** | 0.387 | 1.4 | 1 | 1.6 | 1.9 | 32.7 | 2230 | 500 | D-16 | 1330 |
70** | 0.268 | 1.4 | 1 | 1.6 | 1.9 | 35.9 | 2790 | 500 | D-18 | 1640 |
95** | 0.193 | 1.6 | 1.2 | 2 | 2.1 | 42.1 | 3710 | 500 | D-18 | 2200 |
120** | 0.153 | 1.6 | 1.2 | 2 | 2.2 | 45.3 | 4580 | 500 | D-18 | 2610 |
150** | 0.124 | 1.8 | 1.2 | 2 | 2.3 | 49.1 | 5410 | 500 | D-19 | 3300 |
185** | 0.0991 | 2 | 1.4 | 2.5 | 2.4 | 54.4 | 6890 | 250 | D-18 | 1960 |
240** | 0.0754 | 2.2 | 1.4 | 2.5 | 2.5 | 60.7 | 8430 | 250 | D-18 | 2350 |
300** | 0.0601 | 2.4 | 1.6 | 2.5 | 2.7 | 66.3 | 10140 | 250 | D-18 | 2780 |
400** | 0.047 | 2.6 | 1.6 | 3.15 | 2.9 | 73.3 | 12500 | 250 | D-19 | 3450 |
*Circular solid conductors (Class 1).
All other conductors Circular stranded or circular stranded compacted (Class 2).
All the cables are Insulated with either PVC Type 5 Heat Resisting 85℃ compound and sheathed with PVC
Type 9/ ST2 compound OR PVC Type A/TIl compound and sheathed with PVC Type ST1/TM1 compound.
Cables conform to BS 6346.
* * cables with sector shaped conductors having lesser overall dimensions, weight and cost are available on request.
600 / 1000 V – THREE CORE COPPER CONDUCTOR PVC INSULATED STEEL WIRE ARMOURED PVC SHEATHED CABLES
(CU/PVC/PVC/SWA/PVC and CU/PVC/SWA/PVC)
Nominal Area of Conductor | Maximum Conductor Resistance at 20°C | Thickness of Insulation | Thickness of Bedding | Dia. of Armour Wire | Thickness of Outer Sheath | Approx.Overall Diameter | Approx.Cable Weight | Standard Packing Length | Drum Size | Approx.Gross Weight | ||||
Extruded Bedding | Lapped Bedding | Extruded Bedding | Lapped Bedding | Extruded Bedding | Lapped Bedding | Extruded Bedding | Lapped Bedding | |||||||
Sqmm | Ohm/Km | mm | mm | mm | mm | mm | Kg/Km | Metre±10% | KG | |||||
1.5* | 12.1 | 0.7 | 0.8 | – | 0.9 | 1.4 | 13.3 | – | 340 | – | 1000 | D-10 | 400 | – |
1.5 | 12.1 | 0.7 | 0.8 | – | 0.9 | 1.4 | 13.7 | – | 355 | – | 1000 | D-10 | 415 | – |
2.5* | 7.41 | 0.8 | 0.8 | – | 0.9 | 1.4 | 14.6 | – | 415 | – | 1000 | D-10 | 475 | – |
2.5 | 7.41 | 0.8 | 0.8 | 0.9 | 1.4 | 15 | – | 435 | – | 1000 | D-10 | 495 | – | |
4 | 4.61 | 0.8 | 0.8 | – | 0.9 | 1.4 | 16.1 | – | 515 | – | 1000 | D-11 | 615 | – |
6 | 3.08 | 0.8 | 0.8 | – | 1.25 | 1.5 | 18.3 | – | 720 | – | 1000 | D-12 | 830 | – |
10 | 1.83 | 1 | 0.8 | – | 1.25 | 1.6 | 20.9 | – | 960 | – | 1000 | D-12 | 1070 | – |
16 | 1.15 | 1 | 0.8 | – | 1.25 | 1.6 | 23.2 | – | 1240 | – | 1000 | D-14 | 1390 | – |
25 | 0.727 | 1.2 | 1 | 0.8 | 1.6 | 1.7 | 25.6 | 24.5 | 1670 | 1550 | 500 | D-12 | 945 | 858 |
35 | 0.524 | 1.2 | 1 | 0.8 | 1.6 | 1.8 | 28.1 | 27 | 2050 | 1920 | 500 | D-12 | 1140 | 1070 |
50 | 0.387 | 1.4 | 1 | 0.8 | 1.6 | 1.9 | 31.9 | 30.8 | 2610 | 2460 | 500 | D-14 | 1460 | 1380 |
70 | 0.268 | 1.4 | 1.2 | 0.8 | 2 | 2 | 35.5 | 34 | 3570 | 3360 | 500 | D-16 | 2030 | 1890 |
95 | 0.193 | 1.6 | 1.2 | 0.8 | 2 | 2.1 | 40.3 | 38.8 | 4590 | 4360 | 500 | D-18 | 2540 | 2420 |
120 | 0.153 | 1.6 | 1.2 | 0.8 | 2 | 2.2 | 43.5 | 42 | 5480 | 5230 | 500 | D-18 | 2980 | 2860 |
150 | 0.124 | 1.8 | 1.4 | 0.8 | 2.5 | 2.4 | 47.8 | 45.9 | 6940 | 6600 | 500 | D-19 | 3790 | 3620 |
185 | 0.0991 | 2 | 1.4 | 0.8 | 2.5 | 2.5 | 52.3 | 50.4 | 8270 | 7900 | 250 | D-18 | 2310 | 2220 |
240 | 0.0754 | 2.2 | 1.6 | 0.8 | 2.5 | 2.6 | 59 | 56.7 | 10330 | 9870 | 250 | D-18 | 2820 | 2710 |
300 | 0.0601 | 2.4 | 1.6 | 0.8 | 2.5 | 2.8 | 63.7 | 61.4 | 12480 | 11950 | 250 | D-18 | 3360 | 3230 |
400 | 0.047 | 2.6 | 1.6 | 0.8 | 2.5 | 3 | 71.1 | 68.8 | 15560 | 14970 | 250 | D-19 | 3430 | 3310 |
500 | 0.0366 | 2.8 | 1.8 | 0.8 | 3.15 | 3.6 | 78.8 | 76.1 | 19910 | 19130 | 200 | D-19 | 4300 | 4150 |
*Circular solid conductors (Class 1).
Conductors including 16sqmm circular stranded (Class 2).
25sqmm and above shaped stranded conductors(Class 2)
All the cables are insulated with either PVC Type 5 Heat Resisting 85℃ compound and sheathed with PVC
Type 9/ST2 compound OR PVC Type A/TI1 compound and sheathed with PVC Type ST1/TM1 compound.
Drum size given above are for cables with extruded bedding.
Cables upto 400sqmm conform to BS6346. 500sqmm cable conforms to IEC 60502-1.
600 / 1000 V – FOUR CORE WITH REDUCED NEUTRAL COPPER CONDUCTOR PVC INSULATED STEEL WIRE ARMOURED PVC SHEATHED CABLES
(CU/PVC/PVC/SWA/PVC and CU/PVC/SWA/PVC)
Nominal Area of Conductor | Maximum Conductor Resistance at 20°C | Thickness of Insulation | Thickness of Bedding | Dia. of Armour Wire | Thickness of Outer Sheath | Approx.Overall Diameter | Approx.Cable Weight | Standard Packing Length | Drum Size | Approx.Gross Weight | |||||||
Phase | Neutral | Phase | Neutral | Phase | Neutral | Extruded | Lapped | Extruded Bedding | Lapped Bedding | Extruded Bedding | Lapped Bedding | Extruded Bedding | Lapped Bedding | ||||
Sqmm | Ohm/Km | mm | mm | mm | mm | mm | Kg/Km | Metre±10% | KG | ||||||||
10 * | 6 | 1.83 | 3.08 | 1 | 1 | 1 | – | 1.25 | 1.8 | 22.7 | – | 1080 | – | 1000 | D-14 | 1230 | – |
16* | 10 | 1.15 | 1.83 | 1 | 1 | 1 | – | 1.6 | 1.8 | 25.9 | – | 1530 | – | 500 | D-12 | 875 | – |
25 | 16 | 0.727 | 1.15 | 1.2 | 1 | 1 | 0.8 | 1.6 | 1.8 | 27.9 | 26.8 | 1930 | 1835 | 500 | D-12 | 1080 | 1020 |
35 | 16 | 0.524 | 1.15 | 1.2 | 1 | 1 | 0.8 | 1.6 | 1.9 | 31.5 | 30.4 | 2380 | 2270 | 500 | D-14 | 1340 | 1285 |
50 | 25 | 0.387 | 0.727 | 1.4 | 1.2 | 1 | 0.8 | 2 | 2 | 35.9 | 34.8 | 3250 | 3120 | 500 | D-16 | 1830 | 1770 |
70 | 35 | 0.268 | 0.524 | 1.4 | 1.2 | 1.2 | 0.8 | 2 | 2.1 | 39.4 | 37.9 | 4150 | 3945 | 500 | D-18 | 2315 | 2215 |
95 | 50 | 0.193 | 0.387 | 1.6 | 1.4 | 1.2 | 0.8 | 2 | 2.3 | 44.8 | 43.3 | 5360 | 5125 | 500 | D-18 | 2920 | 2800 |
120 | 70 | 0.153 | 0.268 | 1.6 | 1.4 | 1.4 | 0.8 | 2.5 | 2.5 | 49.3 | 47.4 | 6890 | 6575 | 500 | D-19 | 3765 | 3610 |
150 | 70 | 0.124 | 0.268 | 1.8 | 1.4 | 1.4 | 0.8 | 2.5 | 2.6 | 54 | 51.2 | 8110 | 7665 | 500 | D-19 | 4380 | 4150 |
185 | 95 | 0.0991 | 0.193 | 2 | 1.6 | 1.4 | 0.8 | 2.5 | 2.7 | 58.7 | 56.5 | 9730 | 9305 | 250 | D-18 | 2675 | 2565 |
240 | 120 | 0.0754 | 0.153 | 2.2 | 1.6 | 1.6 | 0.8 | 2.5 | 2.9 | 64.9 | 62.1 | 12030 | 11535 | 250 | D-18 | 3250 | 3125 |
300 | 150 | 0.0601 | 0.124 | 2.4 | 1.8 | 1.6 | 0.8 | 2.5 | 3.1 | 70.2 | 67.9 | 14660 | 13990 | 250 | D-21 | 4090 | 3915 |
300 | 185 | 0.0601 | 0.0991 | 2.4 | 2 | 1.6 | 0.8 | 2.5 | 3.2 | 70.4 | 68.1 | 14870 | 14350 | 250 | D-21 | 4135 | 4000 |
400 | 185 | 0.047 | 0.0991 | 2.6 | 2 | 1.8 | 0.8 | 3.15 | 3.4 | 80.2 | 76.6 | 19090 | 18125 | 200 | D-19 | 4135 | 3945 |
500 | 240 | 0.0366 | 0.0754 | 2.8 | 2.2 | 1.8 | 0.8 | 3.15 | 3.7 | 88.4 | 85.7 | 23300 | 22360 | 200 | D-23 | 5170 | 4970 |
*Phase conductors upto 16sqmm circular stranded(Class 2).
Phase conductors 25sqmm and above shaped stranded (Class 2).
All neutral conductors circular stranded (class 2).
All the cables are insulated with either PVC Type 5 Heat Resisting 85℃ compound and sheathed with PVC
Type 9/ST2 compound OR PVC Type A/TI1 compound and sheathed with PVC Type ST1/TM1 compound.
Drum size given above are for cables with extruded bedding.
*Cables conform to IEC 60502-1
600 / 1000 V – FOUR CORE COPPER CONDUCTOR PVC INSULATED STEEL WIRE ARMOURED PVC SHEATHED CABLES
(CU/PVC/PVC/SWA/PVC and CU/PVC/SWA/PVC)
Nominal Area of Conductor | Maximum Conductor Resistance at 20°C | Thickness of Insulation | Thickness of Bedding | Dia. of Armour Wire | Thickness of Outer Sheath | Approx.Overall Diameter | Approx.Cable Weight | Standard Packing Length | Drum Size | Approx.Gross Weight | ||||
Extruded Bedding | Lapped Bedding | Extruded Bedding | Lapped Bedding | Extruded Bedding | Lapped Bedding | Extruded Bedding | Lapped Bedding | |||||||
Sqmm | Ohm/Km | mm | mm | mm | mm | mm | Kg/Km | Metre±10% | KG | |||||
1.5* | 12.1 | 0.7 | 0.8 | – | 0.9 | 1.4 | 14.1 | – | 385 | – | 1000 | D-10 | 445 | – |
1.5 | 12.1 | 0.7 | 0.8 | – | 0.9 | 1.4 | 14.5 | – | 400 | – | 1000 | D-10 | 460 | – |
2.5* | 7.41 | 0.8 | 0.8 | – | 0.9 | 1.4 | 15.5 | – | 470 | – | 1000 | D-11 | 570 | – |
2.5 | 7.41 | 0.8 | 0.8 | 0.9 | 1.4 | 16 | – | 495 | – | 1000 | D-11 | 595 | – | |
4 | 4.61 | 0.8 | 0.8 | – | 1.25 | 1.5 | 18.1 | – | 700 | – | 1000 | D-12 | 810 | – |
6 | 3.08 | 0.8 | 0.8 | – | 1.25 | 1.5 | 19.6 | – | 8300 | – | 1000 | D-12 | 940 | – |
10 | 1.83 | 1 | 0.8 | – | 1.25 | 1.6 | 22.4 | – | 1130 | – | 1000 | D-14 | 1280 | – |
16 | 1.15 | 1 | 1 | – | 1.6 | 1.7 | 26.4 | – | 1650 | – | 500 | D-12 | 935 | – |
25 | 0.727 | 1.2 | 1 | 0.8 | 1.6 | 1.8 | 27.9 | 26.8 | 2040 | 1890 | 500 | D-12 | 1130 | 1060 |
35 | 0.524 | 1.2 | 1 | 0.8 | 1.6 | 1.9 | 31.5 | 30.4 | 2550 | 2400 | 500 | D-14 | 1430 | 1350 |
50 | 0.387 | 1.4 | 1.2 | 0.8 | 2 | 2 | 36.3 | 34.8 | 3510 | 3300 | 500 | D-16 | 1970 | 1860 |
70 | 0.268 | 1.4 | 1.2 | 0.8 | 2 | 2.1 | 39.4 | 37.9 | 4450 | 4220 | 500 | D-18 | 2470 | 2350 |
95 | 0.193 | 1.6 | 1.2 | 0.8 | 2 | 2.2 | 44.6 | 43.1 | 5770 | 5510 | 500 | D-18 | 3130 | 3000 |
120 | 0.153 | 1.6 | 1.4 | 0.8 | 2.5 | 2.4 | 49.1 | 47.2 | 7350 | 6970 | 500 | D-19 | 4000 | 3810 |
150 | 0.124 | 1.8 | 1.4 | 0.8 | 2.5 | 2.5 | 53.5 | 51.6 | 8760 | 8390 | 250 | D-18 | 2430 | 2340 |
185 | 0.0991 | 2 | 1.4 | 0.8 | 2.5 | 2.6 | 58.6 | 56.3 | 10530 | 10040 | 250 | D-18 | 2870 | 2750 |
240 | 0.0754 | 2.2 | 1.6 | 0.8 | 2.5 | 2.8 | 64.2 | 61.9 | 13050 | 12520 | 250 | D-18 | 3500 | 3370 |
300 | 0.0601 | 2.4 | 1.6 | 0.8 | 2.5 | 3 | 70 | 67.7 | 15880 | 15300 | 250 | D-19 | 4290 | 4150 |
400 | 0.047 | 2.6 | 1.8 | 0.8 | 3.15 | 3.3 | 79.1 | 76.4 | 20710 | 20000 | 200 | D-19 | 4460 | 4320 |
500 | 0.0366 | 2.8 | 1.8 | 0.8 | 3.15 | 3.9 | 88.8 | 86.1 | 25400 | 24720 | 200 | D-23 | 5580 | 5440 |
*Circular solid conductors (Class 1).
Conductors including 16sqmm circular stranded (Class 2).
25sqmm and above shaped stranded conductors(Class 2)
All the cables are insulated with either PVC Type 5 Heat Resisting 85℃ compound and sheathed with PVC
Type 9/ST2 compound OR PVC Type A/TI1 compound and sheathed with PVC Type ST1/TM1 compound.
Drum size given above are for cables with extruded bedding.
Cables upto 400sqmm conform to BS6346. 500sqmm cable conforms to IEC 60502-1.
600 / 1000 V – FIVE CORE COPPER CONDUCTOR PVC INSULATED STEEL WIRE ARMOURED PVC SHEATHED CABLES
(CU/PVC/PVC/SWA/PVC and CU/PVC/SWA/PVC)
Nominal Area of Conductor | Maximum Conductor Resistance at 20°C | Thickness of Insulation | Thickness of Bedding | Dia. of Armour Wire | Thickness of Outer Sheath | Approx.Overall Diameter | Approx.Cable Weight | Standard Packing Length | Drum Size | ||
Extruded Bedding | Lapped Bedding | Extruded Bedding | Lapped Bedding | Extruded Bedding | |||||||
Sqmm | Ohm/Km | mm | mm | mm | mm | mm | Kg/Km | Metre±10% | |||
1.5 | 12.1 | 0.7 | 0.8 | – | 1.25 | 1.8 | 18 | – | 601 | 1000 | D-10 |
2.5 | 7.41 | 0.8 | 0.8 | 1.25 | 1.8 | 19.2 | – | 707 | 1000 | D-11 | |
4 | 4.61 | 0.8 | 0.8 | – | 1.25 | 1.8 | 21.8 | – | 915 | 1000 | D-12 |
6 | 3.08 | 0.8 | 0.8 | – | 1.6 | 1.8 | 24 | – | 1197 | 1000 | D-12 |
10 | 1.83 | 1 | 0.8 | – | 1.6 | 1.8 | 26.5 | – | 1517 | 1000 | D-14 |
16 | 1.15 | 1 | 1 | – | 1.6 | 1.9 | 29.5 | – | 1948 | 500 | D-12 |
25 | 0.727 | 1.2 | 1 | 0.8 | 1.6 | 2 | 33.4 | 29.4 | 2605 | 500 | D-12 |
35 | 0.524 | 1.2 | 1 | 0.8 | 2 | 2.1 | 34.8 | 30.62 | 3283 | 500 | D-14 |
50 | 0.387 | 1.4 | 1.2 | 0.8 | 2 | 2.2 | 39 | 34.62 | 4183 | 500 | D-16 |
70 | 0.268 | 1.4 | 1.2 | 0.8 | 2 | 2.3 | 43.1 | 38.52 | 5394 | 500 | D-18 |
95 | 0.193 | 1.6 | 1.2 | 0.8 | 2.5 | 2.6 | 50.1 | 44.92 | 7487 | 500 | D-18 |
120 | 0.153 | 1.6 | 1.4 | 0.8 | 2.5 | 2.7 | 54.1 | 48.72 | 8935 | 500 | D-19 |
150 | 0.124 | 1.8 | 1.4 | 0.8 | 2.5 | 2.9 | 59.1 | 53.32 | 10711 | 250 | D-18 |
185 | 0.0991 | 2 | 1.4 | 0.8 | 2.5 | 3.1 | 64.9 | 58.72 | 12988 | 250 | D-18 |
240 | 0.0754 | 2.2 | 1.6 | 0.8 | 2.5 | 3.3 | 72.2 | 65.62 | 16369 | 250 | D-18 |
300 | 0.0601 | 2.4 | 1.6 | 0.8 | 3.15 | 3.6 | 80.7 | 73.52 | 20850 | 250 | D-19 |
400 | 0.047 | 2.6 | 1.8 | 0.8 | 3.15 | 3.8 | 88.92 | 81.32 | 25630 | 200 | D-19 |
500 | 0.0366 | 2.8 | 1.8 | 0.8 | 2.5 | 2.5 | 46.8 | 41.8 | 19916 | 200 | D-23 |
*Circular solid conductors (Class 1).
Conductors including 16sqmm circular stranded (Class 2).
25sqmm and above shaped stranded conductors(Class 2)
All the cables are insulated with either PVC Type 5 Heat Resisting 85℃ compound and sheathed with PVC
Type 9/ST2 compound OR PVC Type A/TI1 compound and sheathed with PVC Type ST1/TM1 compound.
Drum size given above are for cables with extruded bedding.
Cables upto 400sqmm conform to BS6346. 500sqmm cable conforms to IEC 60502-1.
Installation:
1. The installation temperature should not over 20℃, If the ambient temperature is lower than 0℃, the cable should be preheated.
2. The bending radius of cable should not less than 8 times.
3. After installantion, the cable should with stand voltage test for 15min. 3.5kv D.C.
Packing: