0.6/1kV XLPE INSULATED ARMORED POWER CABLE

Our company specialized in Cable/Electrical Wire/ Conductor product

0.6/1kV XLPE INSULATED ARMORED POWER CABLE

type:0.6/1kV CU or AL/XLPE/PVC/SWA/PVC

standard:BS 7870-3.10-2001or IEC 60502 -1

construction: CU or AL/XLPE/PVC/SWA/PVC or CU or AL/XLPE/PVC/AWA/PVC

rating voltage:0.6/1kV

conductor material:Copper or aluminum

insulation material:XLPE

armor construction:SWA OR AWA

sheath material:PVC

specification or package can be produced as your request.

INQUIRY

Application:
XLPE INSULATED LAID UP AND PVC SHEATHED CABLE TO IEC60502.1.
0.6/1kV XLPE Cable is used indoor or outdoor, in tunnel, cable furrow or pipe. It able to bear external mechanical forces, but the tractive force during laying.
The concentric conductor is used as a screen and could be used as
neutral (N), earthing (PE), and both as neutral and earthing (PEN) conductor,
but not as an external conductor.
Standards:
BS 7870-3.10-2001or IEC 60502 -1
Construction
• Solid or stranded Cu or AL wires cl. 1 or cl. 2
• Description of the wire’s shape
re - round solid
rm - round multi-core
sm - sector multi-core
• Insulation: XLPE compound
• Inner sheath: filling compound
• Armoring: Steel wire armoured
• Wrapping: polymer tape
• Outer sheath: PVC compound
• Outer sheath colour: black

600/1000 V-TWO CORE COPPER CONDUCTOR XLPE INSULATED SWA PVC SHEATHED CABLES (CU/XLPE/PVC/SWA/PVC)

Nominal Area of Conductor Maximum Conductor Resistance at 20°C Thickness of Insulation Thickness of  Extruded Bedding Dia. of Armour Wire Thickness of Outer Sheath Approx.Overall Diameter Approx.Cable Weight Standard Packing Length Drum Size Approx.Gross Weight
Sqmm Ohm/Km mm mm mm mm mm Kg/Km Metre±10% KG
1.5* 12.1 0.7 1 0.9 1.8 14.2 355 1000 D-10 415
1.5 12.1 0.7 1 0.9 1.8 14.6 370 1000 D-10 430
2.5* 7.41 0.7 1 0.9 1.8 15 400 1000 D-10 460
2.5 7.41 0.7 1 0.9 1.8 15.4 415 1000 D-10 475
4 4.61 0.7 1 0.9 1.8 16.4 480 1000 D-11 580
6 3.08 0.7 1 0.9 1.8 17.6 570 1000 D-11 670
10 1.83 0.7 1 1.25 1.8 20.3 820 1000 D-12 930
16 1.15 0.7 1 1.25 1.8 22.3 1030 1000 D-14 1180
25 0.727 0.9 1 1.6 1.8 26.3 1530 1000 D-16 1740
35 0.524 0.9 1 1.6 1.8 28.5 1840 1000 D-18 2080
50 0.387 1 1 1.6 1.8 30.9 2070 500 D-14 1190
70 0.268 1.1 1 1.6 2 34.9 2670 500 D-16 1545
95 0.193 1.1 1.2 2 2.1 40.1 3660 500 D-18 2070
120 0.153 1.2 1.2 2 2.2 43.7 4350 500 D-18 2420
150 0.124 1.4 1.2 2 2.3 47.5 5160 500 D-19 2900
185 0.0991 1.6 1.4 2.5 2.5 53.3 6600 250 D-18 1895
240 0.0754 1.7 1.4 2.5 2.7 59.1 8100 250 D-18 2270
300 0.0601 1.8 1.6 2.5 2.8 64.1 9660 250 D-18 2660
400 0.047 2 1.6 2.5 3.1 71.3 12000 250 D-21 3425
500 0.0366 2.2 1.6 3.15 3.3 79.8 15500 250 D-23 4375

*Circular solid conductors (Class 1).
All other conductors Circular stranded or circular stranded compacted (Class 2).
Cables conform to BS 5467 and generally to IEC 60502 – 1.

600/1000V-THREE CORE COPPER CONDUCTOR XLPE INSULATED  SWA  PVC SHEATHED CABLES (CU/XLPE/PVC/SWA/PVC)

Nominal Area of Conductor Maximum Conductor Resistance at 20°C Thickness of Insulation Thickness of Bedding Dia. of Armour Wire Thickness of Outer Sheath Approx.Overall Diameter Approx.Cable Weight Standard Packing Length Drum Size Approx.Gross Weight
Extruded Bedding Lapped Bedding Extruded Bedding Lapped Bedding Extruded Bedding Lapped Bedding Extruded Bedding Lapped Bedding
Sqmm Ohm/Km mm mm mm mm mm Kg/Km Metre±10% KG
1.5* 12.1 0.7 0.8 0.9 1.3 13.3 330 1000 D-10 390
1.5 12.1 0.7 0.8 0.9 1.3 13.7 350 1000 D-10 410
2.5* 7.41 0.7 0.8 0.9 1.4 14.4 390 1000 D-10 450
2.5 7.41 0.7 0.8 0.9 1.4 14.8 415 1000 D-10 475
4 4.61 0.7 0.8 0.9 1.4 15.9 490 1000 D-11 590
6 3.08 0.7 0.8 0.9 1.4 17.2 580 1000 D-12 690
10 1.83 0.7 0.8 1.25 1.5 19.6 850 1000 D-12 960
16 1.15 0.7 0.8 1.25 1.6 22.2 1110 1000 D-14 1260
25 0.727 0.9 1 0.8 1.6 1.7 24.3 23.2 1520 1420 500 D-11 870 810
35 0.524 0.9 1 0.8 1.6 1.8 26.9 25.8 1910 1790 500 D-12 1065 1010
50 0.387 1 1 0.8 1.6 1.8 30.1 29 2400 2250 500 D-12 1350 1230
70 0.268 1.1 1 0.8 1.6 1.9 32.8 31.7 3100 2950 500 D-14 1700 1630
95 0.193 1.1 1.2 0.8 2 2.1 38.2 36.7 4310 4060 500 D-16 2400 2270
120 0.153 1.2 1.2 0.8 2 2.2 41.8 40.3 5170 4920 500 D-18 2830 2700
150 0.124 1.4 1.4 0.8 2.5 2.3 46.4 44.5 6620 6290 500 D-18 3550 3390
185 0.0991 1.6 1.4 0.8 2.5 2.4 50.8 48.9 7860 7510 250 D-18 2210 2090
240 0.0754 1.7 1.4 0.8 2.5 2.6 56.9 55 9810 9410 250 D-18 2690 2590
300 0.0601 1.8 1.6 0.8 2.5 2.7 61.8 59.5 11910 11430 250 D-18 3220 3100
400 0.047 2 1.6 0.8 2.5 2.9 69.2 66.9 14910 14330 250 D-19 3300 3110

*Circular solid conductors (Class 1).
Conductors including 16sqmm circular stranded (Class 2).
25sqmm and above shaped stranded conductors(Class 2)
Cables conform to BS 5467 and generally to IEC 60502-1.
600/1000V-FOUR CORE COPPER CONDUCTOR XLPE INSULATED PVC SHEATHED CABLES (CU/XLPE/PVC/SWA/PVC)

Nominal Area of Conductor Maximum Conductor Resistance at 20°C Thickness of Insulation Thickness of Bedding Dia. of Armour Wire Thickness of Outer Sheath Approx.Overall Diameter Approx.Cable Weight Standard Packing Length Drum Size Approx.Gross Weight
Extruded Bedding Lapped Bedding Extruded Bedding Lapped Bedding Extruded Bedding Lapped Bedding Extruded Bedding Lapped Bedding
Sqmm Ohm/Km mm mm mm mm mm Kg/Km Metre±10% KG
1.5* 12.1 0.7 0.8 0.9 1.3 13.3 330 1000 D-10 390
1.5 12.1 0.7 0.8 0.9 1.3 13.7 350 1000 D-10 410
2.5* 7.41 0.7 0.8 0.9 1.4 14.4 390 1000 D-10 450
2.5 7.41 0.7 0.8 0.9 1.4 14.8 415 1000 D-10 475
4 4.61 0.7 0.8 0.9 1.4 15.9 490 1000 D-11 590
6 3.08 0.7 0.8 0.9 1.4 17.2 580 1000 D-12 690
10 1.83 0.7 0.8 1.25 1.5 19.6 850 1000 D-12 960
16 1.15 0.7 0.8 1.25 1.6 22.2 1110 1000 D-14 1260
25 0.727 0.9 1 0.8 1.6 1.7 24.3 23.2 1520 1420 500 D-11 870 810
35 0.524 0.9 1 0.8 1.6 1.8 26.9 25.8 1910 1790 500 D-12 1065 1010
50 0.387 1 1 0.8 1.6 1.8 30.1 29 2400 2250 500 D-12 1350 1230
70 0.268 1.1 1 0.8 1.6 1.9 32.8 31.7 3100 2950 500 D-14 1700 1630
95 0.193 1.1 1.2 0.8 2 2.1 38.2 36.7 4310 4060 500 D-16 2400 2270
120 0.153 1.2 1.2 0.8 2 2.2 41.8 40.3 5170 4920 500 D-18 2830 2700
150 0.124 1.4 1.4 0.8 2.5 2.3 46.4 44.5 6620 6290 500 D-18 3550 3390
185 0.0991 1.6 1.4 0.8 2.5 2.4 50.8 48.9 7860 7510 250 D-18 2210 2090
240 0.0754 1.7 1.4 0.8 2.5 2.6 56.9 55 9810 9410 250 D-18 2690 2590
300 0.0601 1.8 1.6 0.8 2.5 2.7 61.8 59.5 11910 11430 250 D-18 3220 3100
400 0.047 2 1.6 0.8 2.5 2.9 69.2 66.9 14910 14330 250 D-19 3300 3110

600/1000V-FOUR CORE COPPER CONDUCTOR XLPE INSULATED PVC SHEATHED CABLES (CU/XLPE/PVC/SWA/PVC)
*All conductors shaped stranded(Class 2)
Cables conform to IEC 60502-1
Drum size given above are for cables with extruded bedding

Installation:
1. The installation temperature should not over 20℃, If the ambient temperature is lower than 0℃, the cable should be preheated.
2. The bending radius of cable should not less than 8 times.
3. After installantion, the cable should with stand voltage test for 15min. 3.5kv D.C.

INQUIRY

COPYRIGHT © 2017 Henan Province Xinchang Copper Co.,Ltd.