Our company specialized in Cable/Electrical Wire/ Conductor product
H03V2V2H2-F
type:H03V2V2H2-F
standard: IEC 227, VDE 0281, BS 6500
construction:CU/PVC/PVC
rating voltage:300/300V
conductor material:CU
insulation material:PVC
sheath material:PVC
specification or package can be produced as your request.
INQUIRYApplication
Particularly suitable for outdoor applications and for use where flexibility is required at sub zero temperatures.
Votage: 300/300V
Code: H03V2V2H2-F
Standarts: IEC 227, VDE 0281, BS 6500
Construction
•1- Flexible Copper Conductor
• 2- PVC insulation
3-PVC Out Sheath
• Outer sheath colour: black or as required
Technical Data:
Max. operating temperature 70 ºC
Short circuit temperature 160 ºC
Nominal cross-sectional area | Cores No. | Wires No. | Wires. Dia. | Max. Conductor Dia. | Thickness of insulation | Thichness of sheath | Approx. Diameter of cable | Weight per km | Coductor DC resistance at 20℃ | Max. current carrying capacity at 30℃ | Weight per km of Copper | Weight per km of PVC insulation | Weight per km of PVC Sheath | |
(mm2) | (mm) | (mm) | (mm) | (mm) | (mm) | (Kg/km) | (Ω/km) | Pipe A | Air A | (kg/km) | (kg/km) | (kg/km) | ||
0.5 | 2 | 15 | 0.20 | 0.89 | 0.5 | 0.6 | 4.97 | 34.62 | 39 | 3 | 3 | 8.61 | 6.23 | 19.79 |
0.75 | 2 | 22 | 0.20 | 1.08 | 0.5 | 0.6 | 5.35 | 42.21 | 26 | 6 | 6 | 12.62 | 7.08 | 22.50 |
0.5 | 3 | 15 | 0.20 | 0.89 | 0.5 | 0.6 | 5.26 | 41.42 | 39 | 3 | 3 | 12.95 | 9.35 | 19.13 |
0.75 | 3 | 22 | 0.20 | 1.08 | 0.5 | 0.6 | 5.67 | 51.24 | 26 | 6 | 6 | 18.99 | 10.63 | 21.62 |
0.5 | 4 | 15 | 0.20 | 0.89 | 0.5 | 0.6 | 5.76 | 50.93 | 39 | 3 | 3 | 17.26 | 12.46 | 21.20 |
0.75 | 4 | 22 | 0.20 | 1.08 | 0.5 | 0.6 | 6.21 | 63.48 | 26 | 6 | 6 | 25.32 | 14.17 | 23.99 |