Triplex service drop cable

Our company specialized in Cable/Electrical Wire/ Conductor product

Triplex service drop cable

type:ABC

standard:ASTM

construction:AL/XLPE

rating voltage:0.6/1kV

insulation material:XLPE

specification or package can be produced as your request.

INQUIRY

APPLICATIONS
Used to supply power, usually from a pole-mounted transformer, to the user's service head where connection to the service entrance cable is made. To be used at voltages of 600 volts phase-to-phase or less and at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for crosslinked polyethylene (XLP) insulated conductors.
SPECIFICATIONS
Triplex service drop cable meets or exceeds the following ASTM specifications:
• B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
• B-231 Aluminum Conductors, Concentric-Lay-Stranded.
• B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced(ACSR).
• B-399 Stranded 6201-T81 Aluminum Alloy Conductors.
• B-901 Compressed Round Stranded Aluminum Conductors Using Single Input Wire.
Triplex service drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474.
CONSTRUCTION
Conductors are concentrically stranded, compressed 1350-H19 aluminum. Insulated with either polyethylene or crosslinked polyethylene (XLP). Neutral messengers are concentrically stranded 6201, AAC, or ACSR.

 

Code* Word Phase Conductor Bare Neutral Messenger Weight Per 1000 ft.(lbs.) Allowable Ampacities+
Size (AWG Strand- ing Insul. Thick. (mils) Equiv. Dia. (AWG)++ Size++ (kcmil) Strand- ing Rated Strength (lbs). XLP POLY XLP POLY
6201 ALLOY NEUTRAL-MESSENGER
Minex 6 1 45 6 30.58 7 1110 101 101 85 70
Hippa 6 7 45 6 30.58 7 1110 107 107 85 70
Prawn 4 1 45 4 48.69 7 1760 152 152 115 90
Barnacle 4 7 45 4 48.69 7 1760 160 160 115 90
Shrimp 2 7 45 2 77.47 7 2800 243 243 150 120
Gammarus 1/0 7 60 1/0 123.3 7 4460 390 390 205 160
Leda 1/0 9 60 1/0 123.3 7 4460 384 384 205 160
Dungenese 2/0 7 60 2/0 155.4 7 5390 483 483 235 185
Cyclops 2/0 11 60 2/0 155.4 7 5390 474 474 235 185
Flustra 3/0 17 60 3/0 195.7 7 6790 587 587 275 215
Lepas 4/0 18 60 4/0 246.9 7 8560 728 728 315 245
 

*Code words for XLP insulated products are formed by adding “/XLP” to the conventional code words above (e.g.-Haiotis/XLP).

+Conductor temperature of 90°C for XLP, 75°C for Poly; ambient temperature of 40°C; emissivity 0.9; 2 ft./sec. wind in sun.

++Designated sizes are: ACSR 6/1 diameter equivalent and AAC with equivalent resistivity per ASTM B-399 for 6201.

 

Code* Word Phase Conductor Bare Neutral Messenger Weight Per 1000 ft. (lbs.) Allowable Ampacities+
Size (AWG) Strand- ing Insul. Thick. (mils) Equiv. Dia. (AWG)++ Size (kcmil) Strand- ing Rated Strength (lbs.) XLP POLY XLP POLY
6201 ALLOY REDUCED NEUTRAL-MESSENGER
Artemia 4 1 45 6 30.58 7 1110 135 135 115 90
Crab 4 7 45 6 30.58 7 1110 143 143 115 90
Solaster 2 7 45 4 48.69 7 1760 216 216 150 120
Sandcrab 1/0 7 60 2 77.47 7 2800 347 347 205 160
Echinus 1/0 9 60 2 77.47 7 2800 341 341 205 160
Fulgar 3/0 17 60 1/0 123.3 7 4460 519 519 275 215
Arca 4/0 18 60 2/0 155.4 7 5390 643 643 315 245
 

*Code words for XLP insulated products are formed by adding “/XLP” to the conventional code words above (e.g.-Haiotis/XLP).

+Conductor temperature of 90°C for XLP, 75°C for Poly; ambient temperature of 40°C; emissivity 0.9; 2 ft./sec. wind in sun.

++Designated sizes are: ACSR 6/1 diameter equivalent and AAC with equivalent resistivity per ASTM B-399 for 6201.

Packaging:

  1. Wooden drum
  2. Iron frame wooden drum
  3. Iron drum

Container loading:

  1. 20ft GP: 5898mm(Length)x2352mm(Width)x2393(High), loading: 18-25tons;
  2. 40ft GP: 12032mm(Length)x2352mm(Width)x2393(High), loading: 20-28tons;

Port:

Qingdao port or other China main ports

INQUIRY

COPYRIGHT © 2017 Henan Province Xinchang Copper Co.,Ltd.